256, 384 or 640? Choosing thermal resolution by field of view and pixels on target
“Is 256 enough, or do we need 640?” The short answer: the lens decides how much detail each pixel sees, and the resolution decides how wide an area you cover at that detail. Here is how to work it out, with the 21 × 21 mm radiometric cores we sell as the example: 256 × 192, 384 × 288 and 640 × 512, all with 12 μm pixels.
Detail per pixel comes from the lens
Each pixel sees a small angle, the IFOV: pixel pitch divided by focal length. With 12 μm pixels the maker lists 3.05 mrad for the 4 mm lens, 1.76 mrad for 6.8 mm, 1.3 mrad for 9.1 mm, 0.9 mrad for 13.5 mm and 0.7 mrad for 18 mm. At a distance R a pixel covers IFOV × R: with the 9.1 mm lens, about 6.5 mm at 5 m (calculated).
This does not depend on resolution. Put the same lens on a 256 and a 640 and, near the centre of the image, each pixel sees the same patch of the scene. The 640 simply has more pixels.
Width comes from resolution
| Lens (IFOV) | 256 × 192 | 384 × 288 | 640 × 512 |
|---|---|---|---|
| 4 mm F1.1 (3.05 mrad) | 45.5° × 33.5° | 64.1° × 48.8° | About 100° × 82° with a non-standard 4 mm lens |
| 6.8 mm F1.2 (1.76 mrad) | — | 39.3° × 29.4° | — |
| 9.1 mm F1.1 (1.3 mrad) | — | 29.2° × 21.7° | 48.7° × 38.6° |
| 13.5 mm F1.0 (0.9 mrad) | — | — | 31.9° × 25.7° (non-standard) |
| 18 mm F1.1 (0.7 mrad) | — | — | 24.2° × 19.5° (non-standard) |
More pixels across means a wider field of view at the same detail. Two comparisons make the point. The 4 mm lens covers 45.5° on the 256 and 64.1° on the 384, with the same 3.05 mrad pixels. And the 256 with the 4 mm lens (45.5°) and the 640 with the 9.1 mm lens (48.7°) cover about the same width, but the 640’s pixels are about 2.3 times finer: a target can be 2.3 times smaller, or 2.3 times farther away, for the same number of pixels on it (calculated).
Work it out from your target
- Write down the smallest target you must measure and the farthest distance. A common rule is at least 3 × 3 pixels on the target for a reliable reading, so one pixel at that distance must be a third of the target or smaller. That sets the IFOV, and so the lens.
- Write down the width you need to see, and from how far. That sets the field of view, and so the resolution with that lens.
- Check the lens is sharp over your distances. The listed sharp ranges (all fixed focus) are: 4 mm from 0.29 m (on the 256 and 384), 6.8 mm from 0.8 m, 9.1 mm from 1.2 to 5.5 m, 13.5 mm from 3.8 m and 18 mm from 6.14 m.
A worked example (calculated)
Measure parts down to 2 cm across at up to 5 m, along a row of cabinets 3.5 m wide seen from 4 m.
- Detail: 2 cm ÷ 3 ≈ 6.7 mm per pixel at 5 m, so the IFOV must be 1.33 mrad or less. The 9.1 mm lens fits (6.5 mm at 5 m); the 6.8 mm lens gives 8.8 mm, too coarse.
- Width: 3.5 m from 4 m needs 2 × atan(1.75 / 4) ≈ 47° horizontally. With the 9.1 mm lens, the 384 covers 29.2°, about 2.1 m at 4 m; the 640 covers 48.7°, about 3.6 m.
- Result: the 640 with the 9.1 mm lens. A 384 with the 4 mm lens would cover the width (64.1°), but its pixel is about 15 mm at 5 m, so it could only measure targets of about 4.6 cm and larger.
What else changes with resolution
- Data: the 640 has 6.7 times the pixels of the 256 (327,680 against 49,152) and 3 times those of the 384 (calculated). Processing, USB bandwidth and storage grow with it.
- Power: under 0.35 W, 0.42 W and 0.7 W for the 256, 384 and 640 (typical, USB output, 25°C).
- Weight without the lens: under 7 g, 7 g and 8.6 g.
- Size and connector: the same 21 × 21 × 10.3 mm body and the same 50-pin connector and pin assignment on all three, so you can design the board and the core mounting once and choose the resolution later. Size the window and lens opening for the widest combination you might use: the same lens sees a wider angle on a larger sensor.
- Reach: in this family, only the 640 is listed with the longer 13.5 mm and 18 mm lenses (non-standard on the radiometric version).
Don’t buy pixels you don’t need
If a 256 or a 384 puts enough pixels on your target across the width you need, it costs less, draws less power and sends less data. Choose the 640 when you need the width and the detail at the same time, or the reach of the longer lenses.
Figures for the standard combinations are from the maker’s manual. On the 640, the 4 mm, 13.5 mm and 18 mm lenses are non-standard, and samples with them ship within 15 working days of payment. The 256 × 192 and 384 × 288 radiometric versions are also available; ask us for them.
Related guides
Not sure which resolution fits?
Send the smallest target, the distance and the width you need to see. We reply within 24 hours on working days.