Imaging components. Procurement support.

Choosing a 640 × 512 radiometric thermal module with USB-C: 8 things to check before you order a sample

If you are designing a 640 × 512 radiometric thermal module into an OEM product, the headline numbers (resolution, NETD, temperature range) are the easy part. What decides whether the sample works on your bench in the first week is usually something else. Here is the checklist we go through with engineers before a sample ships, with the MINI 640-2 Radiometric we sell as the example; the questions apply to any supplier.

1. Is it really radiometric, and in which ranges?

A non-radiometric module shows heat as an image. A radiometric module is calibrated so each pixel maps to a temperature, not just a grey level. Ask for the ranges and the accuracy statement. This module has two ranges, −20°C to 150°C (high-quality mode) and 100°C to 650°C (wide-range mode), with typical accuracy of ±2°C or ±2%. Also check the ambient range for measurement: here it is −10°C to +70°C, narrower than the −40°C to +80°C imaging range.

2. What does the USB-C cable carry?

Some USB modules give you video only, and temperature needs a separate interface. Ask whether image, temperature data and control all run over the one USB Type-C connection. On this module they do, and the MIPI (2-lane) and DVP versions also carry temperature data.

3. What happens when you plug it into a PC?

The quickest first day is a module that a Windows PC sees as a USB camera, with no driver to install, so you can check the image in minutes. That picture is not a measurement: its brightness is stretched by automatic gain, so the same grey level can mean different temperatures from one frame to the next. Temperature comes through the SDK. A small tip: on a laptop, disable the built-in webcam first, or your capture app may open the wrong camera.

4. In what form do you get the temperature?

Full-frame temperature (one value per pixel, every frame) or spot values only (maximum, minimum and centre)? Full frame is what you want for your own analytics; spot values are simpler for alarms. Ask which the SDK gives you, and at what frame rate. This module runs at 30 Hz.

5. Which host platforms does the SDK support?

Check that the SDK runs on the computer inside your final product before you design in, not after. For this module, TSDK, our SDK, has builds for Linux (Ubuntu, Raspberry Pi and Jetson), has been tested on our modules, comes at no extra charge and is provided after payment is confirmed.

6. Which lens, and how many pixels land on your target?

For a 12 μm, 640 × 512 core, the listed lenses are 9.1 mm F1.1 (48.7° × 38.6°), 13.5 mm F1.0 (31.9° × 25.7°) and 18 mm F1.1 (24.2° × 19.5°). IFOV is pixel pitch divided by focal length: 12 μm / 9.1 mm ≈ 1.3 mrad. Many engineers use 3 × 3 pixels on the target as the minimum for a reliable reading; with the 9.1 mm lens, one pixel at 5 m covers about 6.5 mm, so a target needs to be about 2 cm or larger (calculated).

Check where the lens is sharp, too. The 9.1 mm lens is fixed focus and sharp from 1.2 to 5.5 m, the 13.5 mm from 3.8 m and the 18 mm from 6.14 m. For targets tens of metres away, a longer lens is both sharp at that distance and puts more pixels on the target; a higher-resolution sensor with the same pitch would not.

On a radiometric module the lens is part of the temperature calibration, so decide it before you order samples. The 9.1 mm lens is in stock; 13.5 mm and 18 mm are non-standard, and their samples ship within 15 working days of payment.

7. Shutter or shutterless?

Every uncooled core needs non-uniformity correction. With a shutter, the image freezes for a moment each time it corrects, which matters for continuous measurement and video analytics. Ask which method the module uses in the mode you will run, and how often it corrects. This module lists both shutter correction and shutterless correction.

8. What is in the sample box, and how fast does it ship?

A sample should let you test without building anything first. The MINI 640-2 Radiometric sample is the module with its 9.1 mm F1.1 lens, the USB Type-C board and a USB 2.0 cable; TSDK is provided separately after payment, at no extra charge. Ask about minimum order and lead time too: some suppliers sell single samples from stock, others want a project commitment first. We have no minimum order, the module is in stock, and samples ship within 2–3 working days of payment.

Treat the sample as the real specification

Datasheet values are measured in a laboratory under defined conditions. Treat the sample as the real specification, and confirm the final datasheet before you freeze your design.

View MINI 640-2 Radiometric

Related guides

Ready to order a sample?

Send your application, lens, host platform and the quantity you need. We reply within 24 hours on working days.

Discuss your requirements